Ethylene Dichloride
- CAS Number
- 107-06-2
- HSN Code
- 29031500
- Molecular Formula
- C2H4Cl2
- Catalogue Number
- AL0694A
- Purity
- 99%
- Molecular Weight
- 98.96 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
This AR-grade ethylene dichloride has tighter purity control than technical/synthesis grades, with the same regulatory controls applying. It is a colorless liquid with a density of 1.256 g/mL, making it suitable for various analytical applications.
Also known as 1,2-Dichloroethane.
- Catalogue No.
- AL0694A
- CAS Number
- 107-06-2
- Molecular Formula
- C2H4Cl2
- Molecular Weight
- 98.96 g/mol
- HSN Code
- 29031500
- Grade
- AR (Analytical Reagent)
- Product Form
- Substance
Colorless liquid, density 1.256 g/mL.
- Appearance
- Colorless liquid
- Shelf Life
- 2 years
- Packaging
- 1 L glass bottle
- Storage
- Store in a cool, well-ventilated area away from heat sources.
1.1 — Product identifier
- Chemical Name
- Ethylene Dichloride
- Catalogue No.
- AL0694A
- Product form
- Substance
- CAS Number
- 107-06-2
- EC Number
- 203-588-8
- Grade
- AR
- EC Index Number
- 602-004-00-3
- Chemical Formula
- C2H4Cl2
- HSN Code
- 29031500
- Synonyms
- 1,2-Dichloroethane
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Solvent and reagent in chemical synthesis and analysis.
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Suspected carcinogen, may cause reproductive toxicity.
3.1 — Substance
- Name
- Ethylene Dichloride
- CAS No.
- 107-06-2
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with soap and water. Seek medical attention if irritation develops.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Headache, dizziness, nausea, respiratory distress.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Flammable liquid; vapors may form explosive mixtures with air.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area. Ventilate and contain spill. Use appropriate protective equipment.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Absorb with inert material and dispose of in accordance with local regulations.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use in a fume hood. Wear appropriate personal protective equipment (PPE).
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Keep container tightly closed in a cool, dry, well-ventilated place.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respirator if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Sweet, chloroform-like
- Odour threshold
- Not established
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- 1.5
- Melting point
- -34.04 °C
- Freezing point
- -34.04 °C
- Boiling point
- 83.5 °C
- Flash point
- 12 °C
- Auto-ignition temperature
- 410 °C
- Decomposition temperature
- Not established
- Flammability (solid, gas)
- Flammable liquid
- Vapour pressure
- 8.5 kPa at 20 °C
- Relative vapour density at 20°C
- 3.1
- Density
- 1.256 g/mL
- Solubility
- Miscible with water, ethanol, and ether
- Log Pow
- 1.25
- Viscosity, kinematic
- 0.9 cSt
- Viscosity, dynamic
- 1.1 mPa·s
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- 7.0 - 18.0 vol%
10.1 — Reactivity
- Reactivity
- Stable under normal conditions. Reacts with strong oxidizing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong oxidizers, strong bases, and alkali metals.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 (oral, rat) 300 mg/kg
- Skin corrosion/irritation
- Causes skin irritation.
- Serious eye damage/irritation
- Causes serious eye irritation.
- Respiratory or skin sensitisation
- Not a skin sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause respiratory irritation.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 1184
- UN-No. (IMDG)
- UN 1184
- UN-No. (IATA)
- UN 1184
- UN-No. (ADN)
- UN 1184
- UN-No. (RID)
- UN 1184
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Ethylene dichloride
- Proper Shipping Name (IMDG)
- Ethylene dichloride
- Proper Shipping Name (IATA)
- Ethylene dichloride
- Proper Shipping Name (ADN)
- Ethylene dichloride
- Proper Shipping Name (RID)
- Ethylene dichloride
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 3 (Flammable liquids)
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used in analytical applications requiring purer ethylene dichloride, subject to regulatory end-use control.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL0694A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 98.96 g/mol
| Test | Standard | Observed |
|---|---|---|
| Purity | 99% min | 99.5% |
| Density | 1.256 g/mL | 1.256 g/mL |
| Boiling Point | 83.5 °C | 83.5 °C |
| Moisture Content | <0.1% | 0.05% |
| Residue on Ignition | <0.01% | <0.005% |
| Related Substances | None detected | None detected |
The above product is expected to comply with AR grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| AR | 99% | -34.04 °C / 83.5 °C | <0.1% | <0.01% | None detected | Miscible with water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.