Ruthenium Trichloride
- CAS Number
- 14898-67-0
- HSN Code
- 28439019
- Molecular Formula
- RuCl3·xH2O
- Catalogue Number
- AL2496A
- Purity
- 48% Ru
- Molecular Weight
- 207.43 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Ruthenium trichloride (RuCl3) is a transition metal halide that serves as a significant precursor in various chemical processes, particularly in catalysis. This specific grade contains 48% ruthenium, making it a concentrated source for applications requiring high ruthenium content. The compound is notable for its hygroscopic nature, which allows it to absorb moisture from the air, and its dark coloration, which is characteristic of many metal chlorides. Ruthenium trichloride is utilized in both academic and industrial settings, particularly in the development of catalysts and in materials science.
Also known as Ruthenium(III) chloride, Ruthenium trichloride.
- Catalogue No.
- AL2496A
- CAS Number
- 14898-67-0
- Molecular Formula
- RuCl3·xH2O
- Molecular Weight
- 207.43 g/mol
- HSN Code
- 28439019
- Grade
- Ru 48% (anhydrous basis)
- Product Form
- Substance
Ruthenium trichloride appears as a black to dark brown crystalline solid. It is hygroscopic, meaning it readily absorbs moisture from the environment. The melting point of RuCl3·xH2O is approximately 100 °C (decomposes), while its boiling point is around 200 °C. The density of this compound is approximately 3.5 g/cm³. It is soluble in water, forming a solution that can be used in various chemical reactions. The compound has a strong, pungent odor due to the presence of chlorine.
- Appearance
- Black to dark brown crystalline solid
- Shelf Life
- -
- Packaging
- Typically packaged in airtight containers to prevent moisture absorption
- Storage
- Store in a cool, dry place away from moisture and incompatible materials.
1.1 — Product identifier
- Chemical Name
- Ruthenium Trichloride
- Catalogue No.
- AL2496A
- Product form
- Substance
- CAS Number
- 14898-67-0
- EC Number
- 238-877-9
- Grade
- Ru 48% (anhydrous basis)
- EC Index Number
- Not specified
- Chemical Formula
- RuCl3·xH2O
- HSN Code
- 28439019
- Synonyms
- Ruthenium(III) chloride, Ruthenium trichloride
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Used as a precursor in catalyst preparation and research
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Corrosive to metals; may cause skin and eye irritation.
3.1 — Substance
- Name
- Ruthenium Trichloride
- CAS No.
- 14898-67-0
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash skin thoroughly with soap and water. Seek medical attention if irritation develops.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. Seek medical attention if irritation persists.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- May cause irritation to skin, eyes, and respiratory tract. Symptoms may include redness, itching, and burning sensation.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Non-flammable, but may emit toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Contain spill and prevent entry into waterways. Use appropriate personal protective equipment.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Collect and dispose of in accordance with local regulations. Use appropriate protective equipment during cleanup.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Handle with gloves and avoid contact with skin and eyes. Use in a well-ventilated area.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place, away from moisture and incompatible materials.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if dust or mist is generated.
9.1 — Information on basic physical and chemical properties
- Physical state
- Solid
- Colour
- Black to dark brown
- Odour
- Pungent
- Odour threshold
- Not specified
- pH value
- Not specified
- Relative evaporation rate (butylacetate=1)
- Not specified
- Melting point
- Approx. 100 °C (decomposes)
- Freezing point
- Not specified
- Boiling point
- Approx. 200 °C
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Not flammable
- Vapour pressure
- Not specified
- Relative vapour density at 20°C
- Not specified
- Density
- Approx. 3.5 g/cm³
- Solubility
- Soluble in water
- Log Pow
- Not specified
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not specified
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions, but may react with strong bases and reducing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong bases, reducing agents, and moisture.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Not classified as acutely toxic, but may cause irritation.
- Skin corrosion/irritation
- Causes skin irritation.
- Serious eye damage/irritation
- Causes serious eye irritation.
- Respiratory or skin sensitisation
- Not classified as a sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- Not classified as a specific target organ toxicant.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 3260
- UN-No. (IMDG)
- UN 3260
- UN-No. (IATA)
- UN 3260
- UN-No. (ADN)
- UN 3260
- UN-No. (RID)
- UN 3260
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Corrosive solid, acidic, inorganic, n.o.s. (Ruthenium trichloride)
- Proper Shipping Name (IMDG)
- Corrosive solid, acidic, inorganic, n.o.s. (Ruthenium trichloride)
- Proper Shipping Name (IATA)
- Corrosive solid, acidic, inorganic, n.o.s. (Ruthenium trichloride)
- Proper Shipping Name (ADN)
- Corrosive solid, acidic, inorganic, n.o.s. (Ruthenium trichloride)
- Proper Shipping Name (RID)
- Corrosive solid, acidic, inorganic, n.o.s. (Ruthenium trichloride)
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 8
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Ruthenium trichloride is primarily used as a precursor in the synthesis of ruthenium-based catalysts, which are essential in various chemical reactions, including hydrogenation and oxidation processes. It is also employed in the production of ruthenium nanoparticles for applications in electronics and materials science. Additionally, this compound finds use in the field of organic synthesis, particularly in the development of new catalytic systems. Its high ruthenium content makes it particularly valuable in research and industrial applications where efficiency and effectiveness are critical.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL2496A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 207.43 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay (Ruthenium content) | 48% minimum | 48.5% |
| Moisture content | Not more than 5% | 3.2% |
| Residue on ignition | Not more than 1% | 0.5% |
| Related substances | None detected | None detected |
| Solubility | Soluble in water | Fully soluble in water at room temperature. |
The above product is expected to comply with Ru 48% (anhydrous basis) grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| Ru 48% (anhydrous basis) | 48% Ru | Approx. 100 °C (decomposes) | Not more than 5% | Not more than 1% | None detected | Soluble in water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.