Strontium ICP Standard Solution

1000 mg/L in Nitric Acid For Laboratory Use
CAS Number
-
HSN Code
38229090
Molecular Formula
Sr(NO3)2
Catalogue Number
AL1456C
Purity
1000 mg/L
Molecular Weight
87.62 g/mol

Complies with : IP | BP | USP | EP | ACS

ISO 9001 ISO 14001 GMP COA with every batch

Sign In

Sign in to view pricing and place your order.

Don't have an account? Create one

Key Properties

Appearance Clear, colorless liquid
Shelf Life -
Packaging -
Storage Store in a cool, dry place away from incompatible materials.

Strontium ICP standard solution is a certified reference solution specifically designed for the calibration of Inductively Coupled Plasma (ICP) spectrometers for the accurate determination of strontium concentrations. This solution contains strontium in a concentration of 1000 mg/L, dissolved in dilute nitric acid, making it suitable for various analytical applications. The solution is prepared under stringent quality control measures to ensure its reliability and consistency, which is crucial for obtaining precise analytical results. As a certified reference material, it is essential for laboratories that require high accuracy in their strontium measurements, particularly in environmental, geological, and materials science studies.

Also known as Strontium Nitrate Solution.

Catalogue No.
AL1456C
CAS Number
-
Molecular Formula
Sr(NO3)2
Molecular Weight
87.62 g/mol
HSN Code
38229090
Grade
1000 mg/L in Nitric Acid
Product Form
Mixture

The Strontium ICP standard solution is a clear, colorless liquid with an acidic nature, characterized by a density of 1.013 g/mL. It is soluble in water due to its ionic nature, and the solution exhibits a pH typical of dilute nitric acid, which is generally around 1-2. The boiling point of the solution is influenced by the concentration of nitric acid, typically around 100°C, while the freezing point is also affected by the acid concentration, generally remaining above 0°C. The solution is stable under normal laboratory conditions but should be stored properly to maintain its integrity.

Appearance
Clear, colorless liquid
Shelf Life
-
Packaging
-
Storage
Store in a cool, dry place away from incompatible materials.

1.1 — Product identifier

Chemical Name
Strontium ICP Standard Solution
Catalogue No.
AL1456C
Product form
Mixture
CAS Number
Not applicable
EC Number
Not applicable
Grade
1000 mg/L in Nitric Acid
EC Index Number
Not applicable
Chemical Formula
Sr(NO3)2
HSN Code
38229090
Synonyms
Strontium Nitrate Solution

1.2 — Relevant identified uses of the substance or mixture and uses advised against

Use of the substance/mixture
Calibration of ICP spectrometers for strontium analysis
Uses advised against
Not specified

1.3 — Details of the supplier of the safety data sheet

Company identification
Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.

1.4 — Emergency Contact Details

Phone / e-Mail
Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in

2.3 — Other hazards

Other hazards
Corrosive to metals; may cause skin and eye irritation.

3.1 — Substance

Name
Strontium ICP Standard Solution
CAS No.
Not applicable

4.1 — Description of first aid measures

First-aid measures after inhalation
Move to fresh air. If symptoms persist, seek medical attention.
First-aid measures after skin contact
Wash skin thoroughly with soap and water. Remove contaminated clothing. Seek medical attention if irritation develops.
First-aid measures after eye contact
Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. Seek medical attention.
First-aid measures after ingestion
Do not induce vomiting. Rinse mouth and seek medical attention immediately.

4.2 — Most important symptoms and effects, both acute and delayed

Symptoms relating to use
Irritation of the respiratory tract, skin, and eyes; potential corrosive effects.

4.3 — Indication of any immediate medical attention and special treatment needed

General information
Treat symptomatically. Show this safety data sheet to the treating physician.

5.1 — Extinguishing media

Suitable extinguishing media
Water spray, carbon dioxide, dry chemical powder, foam.
Unsuitable extinguishing media
Not specified

5.2 — Special hazards arising from the substance or mixture

Special procedures
Non-flammable, but may emit toxic fumes in a fire.

5.3 — Advice for firefighters

Protection during firefighting
Do not enter fire area without proper protective equipment, including respiratory protection.

6.1.1 — For non-emergency personnel

Emergency procedures
Contain spill and absorb with inert material. Dispose of in accordance with local regulations.

6.3 — Methods and material for containment and cleaning up

Methods for cleaning up
Neutralize with a suitable agent and collect for disposal.

6.4 — Reference to other sections

Reference
Not specified

7.1 — Precautions for safe handling

Precautions for safe handling
Use personal protective equipment (PPE) such as gloves and goggles. Avoid contact with skin and eyes.
Hygiene measures
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

7.2 — Conditions for safe storage, including any incompatibilities

Storage conditions
Store in a cool, dry place, away from incompatible substances such as strong bases and oxidizers.

8.2 — Exposure controls

Hand protection
Protective gloves (e.g. nitrile rubber)
Eye protection
Chemical safety goggles or safety glasses
Skin and body protection
Wear suitable protective clothing
Respiratory protection
Use appropriate respiratory protection if ventilation is inadequate.

9.1 — Information on basic physical and chemical properties

Physical state
Liquid
Colour
Colorless
Odour
Odourless
Odour threshold
Not applicable
pH value
1-2
Relative evaporation rate (butylacetate=1)
Not applicable
Melting point
Not applicable
Freezing point
Not applicable
Boiling point
~100°C
Flash point
Not applicable
Auto-ignition temperature
Not applicable
Decomposition temperature
Not applicable
Flammability (solid, gas)
Not applicable
Vapour pressure
Not applicable
Relative vapour density at 20°C
Not applicable
Density
1.013 g/mL
Solubility
Soluble in water
Log Pow
Not applicable
Viscosity, kinematic
Not applicable
Viscosity, dynamic
Not applicable
Explosive properties
Not applicable
Oxidising properties
Not applicable
Explosive limits
Not applicable

10.1 — Reactivity

Reactivity
Stable under normal conditions; avoid contact with strong bases and oxidizing agents.

10.2 — Chemical stability

Chemical stability
Stable under recommended storage conditions.

10.3 — Possibility of hazardous reactions

Possibility of hazardous reactions
No dangerous reactions known under normal conditions of use.

10.4 — Conditions to avoid

Conditions to avoid
Avoid contact with incompatible materials and excessive heat.

10.5 — Incompatible materials

Incompatible materials
Strong bases, oxidizing agents.

10.6 — Hazardous decomposition products

Hazardous decomposition products
Not specified

11.1 — Information on toxicological effects

Acute toxicity
Low toxicity; may cause irritation.
Skin corrosion/irritation
Causes skin irritation.
Serious eye damage/irritation
Causes serious eye irritation.
Respiratory or skin sensitisation
Not a skin sensitizer.
Germ cell mutagenicity
Not classified
Carcinogenicity
Not classified
Specific target organ toxicity (single exposure)
Not classified as a specific target organ toxicant.
Specific target organ toxicity (repeated exposure)
Not classified

12.1 — Toxicity

Toxicity information
Not specified

12.2 — Persistence - degradability

Persistence - degradability
Not specified

12.3 — Bioaccumulative potential

Bioaccumulative potential
Not specified

12.4 — Mobility in soil

Mobility in soil
Not specified

12.6 — Other adverse effects

Environmental precautions
Not specified

13.1 — Waste treatment methods

Additional Info
Dispose of contents/container in accordance with local, regional, national and international regulations.

14.1 — UN number

UN-No. (ADR)
UN 3264
UN-No. (IMDG)
UN 3264
UN-No. (IATA)
UN 3264
UN-No. (ADN)
UN 3264
UN-No. (RID)
UN 3264

14.2 — UN proper shipping name

Proper Shipping Name (ADR)
Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)
Proper Shipping Name (IMDG)
Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)
Proper Shipping Name (IATA)
Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)
Proper Shipping Name (ADN)
Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)
Proper Shipping Name (RID)
Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)

14.3 — Transport hazard class(es)

Transport hazard class(es)
8

14.4 — Packing group

Packing group (ADR)
III
Packing group (IMDG)
III
Packing group (IATA)
III
Packing group (ADN)
III
Packing group (RID)
III

14.5 — Environmental hazards

Dangerous for the environment
Not specified
Marine pollutant
Not specified
Other information
No supplementary information available

15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture

15.1.1 EU-Regulations
Not specified

This Strontium ICP standard solution is primarily used for calibrating ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry) instruments, which are essential for quantitative analysis of strontium in various samples. It finds applications in environmental monitoring, such as analyzing strontium levels in water and soil samples, as well as in the geological field for mineral analysis. Additionally, it is utilized in materials science for studying strontium's role in various compounds and in the manufacturing of strontium-based materials. The solution is also valuable in quality control processes in laboratories that require precise strontium measurements.

ISO 9001 ISO 14001 GMP COA with every batch
Batch Number
AL-2026-AL1456C
Manufacturing Date
September-2026
Expiry Date
September-2031
Molecular Weight
87.62 g/mol
Test Standard Observed
Assay (Strontium) 1000 mg/L ± 5% 1000 mg/L
pH 1-2 1.5
Density 1.010 - 1.015 g/mL 1.013 g/mL
Appearance Clear, colorless Clear, colorless liquid

The above product is expected to comply with 1000 mg/L in Nitric Acid grade specification.

Technical Data Sheet

Grade Assay/Purity Melting/Boiling Point Moisture/LOD Residue on Ignition Related Substances Solubility
1000 mg/L in Nitric Acid 1000 mg/L ~100°C Not specified Not specified Not specified Soluble in water
View full Technical Data Sheet

Related Products

View All

Why buy from Alpha Chemika

Trusted Quality ISO 9001:2015 Certified
Global Supply 125+ Countries Served
Complete Documentation COA, MSDS, TDS & more
Expert Support We're here to help

What Our Scientific & Industrial Customers Say

“Speedy delivery, professional staff.”

Sonica Lokhandwala

“One shop stop for all laboratory chemicals requirements.”

Adebowale Idris

“Exactly as advertised.”

Babatunde Ugwuanyi

“Alpha Chemika products are of excellent quality. Highly satisfied.”

Jack Roberts

“From ordering to shipping, every course of action was smooth. Timely delivery.”

Priti Mourya

“Completely satisfied with the products and services.”

Hitu Kunjathur
FAQs

Common Questions About Laboratory Chemicals & Solutions

Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.

Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.

Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.

Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.

Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.

Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.

Connect with Us for Your Requirements

Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.

Email Address info@alphachemika.net
Phone Number +91 9769472001

Request a Quote

Tell us about your requirement, and our team will get back to you with the right product recommendations and technical support.

  • No countries found

Fields marked * are required. By submitting this form you agree to be contacted by Alpha Chemika regarding your enquiry.

Alpha Chemika Assistant Product search & quotations
Thinking…

items in your quote

Your Quote Request ( items)

Currency: