Sulfuric Acid
- CAS Number
- 7664-93-9
- HSN Code
- 28070010
- Molecular Formula
- H2SO4
- Catalogue Number
- AL01492
- Purity
- 98%
- Molecular Weight
- 98.08 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
SULPHURIC ACID 98% AR is a high-purity analytical reagent known for its exceptional quality and reliability in laboratory applications. This AR-grade sulfuric acid is specifically formulated to meet stringent purity standards, making it ideal for precise trace-metal analytical use. With a molecular weight of 98.08 g/mol and a CAS number of 7664-93-9, it is a vital chemical in various analytical procedures. Its high concentration and purity make it suitable for applications requiring accurate and reproducible results, particularly in the fields of chemistry and materials science.
Also known as Oil of vitriol, Sulphuric acid, Hydrogen sulfate.
- Catalogue No.
- AL01492
- CAS Number
- 7664-93-9
- Molecular Formula
- H2SO4
- Molecular Weight
- 98.08 g/mol
- HSN Code
- 28070010
- Grade
- AR grade
- Product Form
- Substance
SULPHURIC ACID 98% AR is a colorless to pale yellow viscous liquid with a density of 1.84 g/mL at 20°C. It has a boiling point of approximately 338°C and a melting point of -3°C. The acid is highly soluble in water, releasing a significant amount of heat upon dilution. Its refractive index is about 1.40, and it has a pH value of less than 1, indicating its strong acidic nature. The vapor pressure of sulfuric acid at 20°C is very low, around 0.3 mmHg, which contributes to its stability under normal laboratory conditions.
- Appearance
- Colorless to pale yellow viscous liquid
- Shelf Life
- -
- Packaging
- -
- Storage
- Store in a cool, dry, well-ventilated area away from incompatible materials.
1.1 — Product identifier
- Chemical Name
- Sulfuric Acid
- Catalogue No.
- AL01492
- Product form
- Substance
- CAS Number
- 7664-93-9
- EC Number
- 231-639-5
- Grade
- AR grade
- EC Index Number
- 016-020-00-8
- Chemical Formula
- H2SO4
- HSN Code
- 28070010
- Synonyms
- Oil of vitriol, Sulphuric acid, Hydrogen sulfate
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Analytical reagent, industrial applications
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Corrosive to metals, causes severe skin burns and eye damage.
3.1 — Substance
- Name
- Sulfuric Acid
- CAS No.
- 7664-93-9
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If breathing is difficult, give oxygen. Seek medical attention immediately.
- First-aid measures after skin contact
- Remove contaminated clothing and rinse skin with plenty of water for at least 15 minutes. Seek medical attention if irritation persists.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Severe burns, respiratory distress, eye damage, gastrointestinal irritation.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Non-flammable, but can cause fire and explosion in contact with organic materials.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Contain spill and neutralize with lime or sodium bicarbonate. Avoid contact with water.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Use appropriate protective equipment. Absorb spill with inert material and dispose of in accordance with local regulations.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Always add acid to water, never the reverse. Use appropriate personal protective equipment (PPE) including gloves and goggles.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry, well-ventilated area away from incompatible materials such as bases and organic compounds.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless to pale yellow
- Odour
- Odourless
- Odour threshold
- Not applicable
- pH value
- <1
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- -3°C
- Freezing point
- Not applicable
- Boiling point
- 338°C
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not applicable
- Flammability (solid, gas)
- Not applicable
- Vapour pressure
- 0.3 mmHg at 20°C
- Relative vapour density at 20°C
- Not applicable
- Density
- 1.84 g/mL
- Solubility
- Fully miscible with water
- Log Pow
- Not applicable
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not applicable
- Oxidising properties
- Not applicable
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Reacts violently with water and can cause exothermic reactions with bases and organic materials.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong bases, organic materials, and reducing agents.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 (oral, rat) > 2140 mg/kg.
- Skin corrosion/irritation
- Causes severe skin burns.
- Serious eye damage/irritation
- Causes serious eye damage.
- Respiratory or skin sensitisation
- Not a skin sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause respiratory irritation.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 1830
- UN-No. (IMDG)
- UN 1830
- UN-No. (IATA)
- UN 1830
- UN-No. (ADN)
- UN 1830
- UN-No. (RID)
- UN 1830
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Sulfuric Acid
- Proper Shipping Name (IMDG)
- Sulfuric Acid
- Proper Shipping Name (IATA)
- Sulfuric Acid
- Proper Shipping Name (ADN)
- Sulfuric Acid
- Proper Shipping Name (RID)
- Sulfuric Acid
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 8
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
SULPHURIC ACID 98% AR is widely used in laboratories as an analytical-grade acid reagent, particularly for trace-metal digestion and preparation of samples for Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma (ICP) analysis. It is essential in the production of fertilizers, in petroleum refining, and in the manufacture of chemicals. Additionally, it serves as a dehydrating agent and is utilized in various industrial processes, including the synthesis of explosives and in the production of lead-acid batteries.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL01492
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 98.08 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay | 98% | 98.5% |
| Density | 1.84 g/mL | 1.84 g/mL |
| pH | <1 | 0.5 |
| Moisture content | <0.5% | 0.3% |
| Residue on ignition | <0.01% | <0.005% |
| Related substances | None detected | None detected |
The above product is expected to comply with AR grade grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| AR grade | 98% | -3°C / 338°C | <0.5% | <0.01% | None detected | Fully miscible in water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.