Zinc ICP Standard Solution
- CAS Number
- -
- HSN Code
- 38229090
- Molecular Formula
- Zn(NO3)2
- Catalogue Number
- AL2596A
- Purity
- 1000 mg/L Zn
- Molecular Weight
- 65.37 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Zinc ICP standard solution is a certified reference solution specifically formulated for the calibration of Inductively Coupled Plasma (ICP) spectrometers, which are essential for accurate zinc determination in various samples. This solution contains zinc in a concentration of 1000 mg/L, dissolved in dilute nitric acid, ensuring stability and reliability for analytical applications. The molecular weight of the zinc component is 65.37 g/mol, making it a critical standard for laboratories requiring precise measurements of zinc concentrations. The solution is notable for its clarity and colorlessness, indicating a high level of purity and suitability for analytical use.
Also known as Zinc Nitrate Solution.
- Catalogue No.
- AL2596A
- CAS Number
- -
- Molecular Formula
- Zn(NO3)2
- Molecular Weight
- 65.37 g/mol
- HSN Code
- 38229090
- Grade
- 1000 mg/L in Nitric Acid
- Product Form
- Mixture
The Zinc ICP standard solution is a clear, colorless liquid with an acidic pH due to the presence of nitric acid. It has a density of approximately 1.01 g/cm³, typical for dilute acid solutions. The boiling point of the solution is around 100 °C, while the freezing point is approximately 0 °C, consistent with aqueous solutions. This solution is highly soluble in water, as it is already in an aqueous form, and it exhibits a strong acidic character due to the nitric acid content.
- Appearance
- Clear, colorless liquid
- Shelf Life
- -
- Packaging
- Available in 100 mL and 500 mL bottles
- Storage
- Store in a cool, dry place away from direct sunlight.
1.1 — Product identifier
- Chemical Name
- Zinc ICP Standard Solution
- Catalogue No.
- AL2596A
- Product form
- Mixture
- CAS Number
- Not applicable
- EC Number
- Not applicable
- Grade
- 1000 mg/L in Nitric Acid
- EC Index Number
- Not applicable
- Chemical Formula
- Zn(NO3)2
- HSN Code
- 38229090
- Synonyms
- Zinc Nitrate Solution
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Calibration standard for ICP spectrometers
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Corrosive to metals
3.1 — Substance
- Name
- Zinc ICP Standard Solution
- CAS No.
- Not applicable
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with plenty of soap and water. Seek medical attention if irritation develops.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. Seek medical attention.
- First-aid measures after ingestion
- Rinse mouth. Do NOT induce vomiting. Seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- May cause irritation to skin, eyes, and respiratory tract.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Non-flammable, but may emit toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Contain spill and absorb with inert material. Dispose of in accordance with local regulations.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Neutralize with a suitable alkaline material and collect for disposal.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use personal protective equipment (PPE) such as gloves and goggles. Avoid contact with skin and eyes.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place, in a tightly closed container.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use in a well-ventilated area. If exposure limits are exceeded, use appropriate respiratory protection.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Odorless
- Odour threshold
- Not applicable
- pH value
- < 1
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- Not applicable
- Freezing point
- 0 °C
- Boiling point
- 100 °C
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not applicable
- Flammability (solid, gas)
- Not applicable
- Vapour pressure
- Not applicable
- Relative vapour density at 20°C
- Not applicable
- Density
- 1.01 g/cm³
- Solubility
- Fully miscible in water
- Log Pow
- Not applicable
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not applicable
- Oxidising properties
- Not applicable
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions. Avoid contact with strong bases and reducing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong bases, reducing agents, and reactive metals.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Harmful if swallowed or in contact with skin.
- Skin corrosion/irritation
- Causes skin irritation.
- Serious eye damage/irritation
- Causes serious eye damage.
- Respiratory or skin sensitisation
- Not a skin sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause respiratory irritation.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 3264
- UN-No. (IMDG)
- UN 3264
- UN-No. (IATA)
- UN 3264
- UN-No. (ADN)
- UN 3264
- UN-No. (RID)
- UN 3264
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Corrosive liquid, acidic, inorganic, n.o.s. (Zinc Nitrate Solution)
- Proper Shipping Name (IMDG)
- Corrosive liquid, acidic, inorganic, n.o.s. (Zinc Nitrate Solution)
- Proper Shipping Name (IATA)
- Corrosive liquid, acidic, inorganic, n.o.s. (Zinc Nitrate Solution)
- Proper Shipping Name (ADN)
- Corrosive liquid, acidic, inorganic, n.o.s. (Zinc Nitrate Solution)
- Proper Shipping Name (RID)
- Corrosive liquid, acidic, inorganic, n.o.s. (Zinc Nitrate Solution)
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 8
14.4 — Packing group
- Packing group (ADR)
- III
- Packing group (IMDG)
- III
- Packing group (IATA)
- III
- Packing group (ADN)
- III
- Packing group (RID)
- III
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
This Zinc ICP standard solution is primarily used in laboratories for the calibration of ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry) instruments, which are critical for quantitative analysis of zinc in various matrices, including environmental samples, food products, and biological materials. It is also utilized in quality control processes to ensure the accuracy of zinc measurements in industrial applications, such as metal processing and manufacturing. Additionally, this solution serves as a reference material for method validation and development in analytical chemistry.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL2596A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 65.37 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay (Zn) | 1000 mg/L | 1000 mg/L |
| pH | < 1 | 0.8 |
| Density | 1.01 g/cm³ | 1.01 g/cm³ |
| Appearance | Clear, colorless | Clear, colorless |
| Solubility | Fully miscible in water | Fully miscible in water |
The above product is expected to comply with 1000 mg/L in Nitric Acid grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 1000 mg/L | 1000 mg/L Zn | Not applicable | Not specified | Not specified | Not specified | Fully miscible in water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.