Acetone
- CAS Number
- 67-64-1
- HSN Code
- 29141100
- Molecular Formula
- (CH3)2CO
- Catalogue Number
- AL0011C
- Purity
- 99.50%
- Molecular Weight
- 58.08 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
This electronic-grade acetone is refined to very low particulate and ionic impurity levels for cleaning sensitive components.
Also known as 2-Propanone, Dimethyl ketone.
- Catalogue No.
- AL0011C
- CAS Number
- 67-64-1
- Molecular Formula
- (CH3)2CO
- Molecular Weight
- 58.08 g/mol
- HSN Code
- 29141100
- Grade
- Electronic grade
- Product Form
- Substance
Clear, colorless liquid with a density of 0.791 g/mL and very low particulate content.
- Appearance
- Clear, colorless liquid
- Shelf Life
- -
- Packaging
- -
- Storage
- Store in a cool, well-ventilated area away from sources of ignition.
1.1 — Product identifier
- Chemical Name
- Acetone
- Catalogue No.
- AL0011C
- Product form
- Substance
- CAS Number
- 67-64-1
- EC Number
- 200-662-2
- Grade
- Electronic grade
- EC Index Number
- 606-001-00-8
- Chemical Formula
- (CH3)2CO
- HSN Code
- 29141100
- Synonyms
- 2-Propanone, Dimethyl ketone
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Solvent for cleaning and degreasing in electronic applications.
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Vapor may cause drowsiness or dizziness.
3.1 — Substance
- Name
- Acetone
- CAS No.
- 67-64-1
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with soap and water. If irritation occurs, seek medical attention.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. If irritation persists, seek medical attention.
- First-aid measures after ingestion
- Rinse mouth. Do NOT induce vomiting. Seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Headache, dizziness, confusion, and irritation of the eyes and skin.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Highly flammable; vapors may form explosive mixtures with air.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and eliminate all ignition sources. Ventilate area.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Contain spill with inert material and transfer to appropriate waste disposal container.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use only in well-ventilated areas. Avoid contact with skin and eyes.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Keep container tightly closed in a cool, dry, well-ventilated place.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Sweet, characteristic
- Odour threshold
- Not specified
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- >1
- Melting point
- -95 °C
- Freezing point
- -95 °C
- Boiling point
- 56 °C
- Flash point
- -20 °C
- Auto-ignition temperature
- 465 °C
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Flammable liquid
- Vapour pressure
- 233 mmHg at 20 °C
- Relative vapour density at 20°C
- 2.0
- Density
- 0.791 g/mL
- Solubility
- Miscible with water, ethanol, and ether
- Log Pow
- -0.24
- Viscosity, kinematic
- 0.32 cSt at 20 °C
- Viscosity, dynamic
- 0.32 mPa·s at 20 °C
- Explosive properties
- Not explosive under normal conditions
- Oxidising properties
- Not oxidizing
- Explosive limits
- 2.5 - 12.8% (v/v) in air
10.1 — Reactivity
- Reactivity
- Stable under normal conditions. Avoid heat, sparks, and open flames.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong oxidizing agents, strong acids, and bases.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 (oral, rat) 5800 mg/kg
- Skin corrosion/irritation
- Causes mild skin irritation.
- Serious eye damage/irritation
- Causes serious eye irritation.
- Respiratory or skin sensitisation
- Not a skin sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause drowsiness or dizziness.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 1090
- UN-No. (IMDG)
- UN 1090
- UN-No. (IATA)
- UN 1090
- UN-No. (ADN)
- UN 1090
- UN-No. (RID)
- UN 1090
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Acetone
- Proper Shipping Name (IMDG)
- Acetone
- Proper Shipping Name (IATA)
- Acetone
- Proper Shipping Name (ADN)
- Acetone
- Proper Shipping Name (RID)
- Acetone
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 3
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used for cleaning semiconductor components, circuit boards, and optical parts without leaving residue.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL0011C
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 58.08 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay | 99.50% min | 99.75% |
| Moisture Content | <0.1% | 0.05% |
| Residue on Ignition | <0.01% | 0.005% |
| Related Substances | <0.1% | 0.03% |
| Solubility | Miscible with water | Miscible |
The above product is expected to comply with Electronic grade grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| Electronic grade | 99.50% | -95 °C / 56 °C | <0.1% | <0.01% | <0.1% | Miscible with water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.