Iodine Solution
- CAS Number
- -
- HSN Code
- 38229090
- Molecular Formula
- I2 (aq.)
- Catalogue Number
- AL0828C
- Purity
- 0.5M (1N)
- Molecular Weight
- 253.81 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
This is a certified standardized 0.5M (1N) iodine solution, a more concentrated version for volumetric analysis. It is used as a titrant in various analytical procedures due to its oxidizing properties.
Also known as Iodine Titrant, Iodine Standard Solution.
- Catalogue No.
- AL0828C
- CAS Number
- -
- Molecular Formula
- I2 (aq.)
- Molecular Weight
- 253.81 g/mol
- HSN Code
- 38229090
- Grade
- 0.5M (1N)
- Product Form
- Mixture
Dark brown liquid with a density of 1.22 g/mL. The solution is stable under recommended storage conditions and has a characteristic iodine odor.
- Appearance
- Dark brown liquid
- Shelf Life
- 12 months
- Packaging
- Available in 500 mL glass bottles
- Storage
- Store in a cool, dark place away from light and incompatible materials.
1.1 — Product identifier
- Chemical Name
- Iodine Solution
- Catalogue No.
- AL0828C
- Product form
- Mixture
- CAS Number
- Not applicable
- EC Number
- 231-442-4
- Grade
- 0.5M (1N)
- EC Index Number
- Iodine, 7553-56-2
- Chemical Formula
- I2 (aq.)
- HSN Code
- 38229090
- Synonyms
- Iodine Titrant, Iodine Standard Solution
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Analytical reagent for volumetric analysis
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Corrosive to metals, may cause skin burns and eye damage.
3.1 — Substance
- Name
- Iodine Solution
- CAS No.
- Not applicable
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with plenty of soap and water. Seek medical attention if irritation develops.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Rinse mouth. Do NOT induce vomiting. Seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Irritation of the respiratory tract, skin burns, and eye damage.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Iodine is not flammable but may emit toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Contain spill and absorb with inert material. Dispose of in accordance with local regulations.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Use appropriate protective equipment. Clean up spills immediately and dispose of waste properly.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Avoid contact with skin and eyes. Use in a well-ventilated area and wear appropriate protective equipment.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dark place, away from incompatible materials such as strong bases and reducing agents.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Dark brown
- Odour
- Characteristic iodine odor
- Odour threshold
- Not determined
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- Not determined
- Melting point
- Not applicable
- Freezing point
- Not applicable
- Boiling point
- Not determined
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not determined
- Flammability (solid, gas)
- Not applicable
- Vapour pressure
- Not determined
- Relative vapour density at 20°C
- Not determined
- Density
- 1.22 g/mL
- Solubility
- Soluble in water
- Log Pow
- Not determined
- Viscosity, kinematic
- Not determined
- Viscosity, dynamic
- Not determined
- Explosive properties
- Not explosive
- Oxidising properties
- Oxidizing agent
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions. Reacts with strong reducing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong bases, reducing agents, and organic materials.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Toxic if swallowed, inhaled, or absorbed through skin.
- Skin corrosion/irritation
- Causes skin burns and irritation.
- Serious eye damage/irritation
- Causes serious eye damage.
- Respiratory or skin sensitisation
- May cause allergic skin reactions in sensitive individuals.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause respiratory irritation.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- Not assigned
- UN-No. (IMDG)
- Not assigned
- UN-No. (IATA)
- Not assigned
- UN-No. (ADN)
- Not assigned
- UN-No. (RID)
- Not assigned
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Iodine Solution
- Proper Shipping Name (IMDG)
- Iodine Solution
- Proper Shipping Name (IATA)
- Iodine Solution
- Proper Shipping Name (ADN)
- Iodine Solution
- Proper Shipping Name (RID)
- Iodine Solution
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- Not classified as hazardous
14.4 — Packing group
- Packing group (ADR)
- Not applicable
- Packing group (IMDG)
- Not applicable
- Packing group (IATA)
- Not applicable
- Packing group (ADN)
- Not applicable
- Packing group (RID)
- Not applicable
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used directly as a concentrated standardized oxidant titrant in volumetric analysis, particularly in redox titrations and iodine value determinations.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL0828C
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 253.81 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay (Iodine) | 0.5M (1N) | 0.5M |
| Density | 1.22 g/mL | 1.22 g/mL |
| Moisture Content | Not more than 0.5% | 0.3% |
| Residue on Ignition | Not more than 0.1% | 0.05% |
| Related Substances | None detected | None detected |
The above product is expected to comply with 0.5M (1N) grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 0.5M (1N) | 0.5M (1N) | Not applicable | Not more than 0.5% | Not more than 0.1% | None detected | Soluble in water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.