Pivaloyl chloride

98% Extra Pure For Laboratory Use
CAS Number
3282-30-2
HSN Code
29159070
Molecular Formula
C5H9ClO
Catalogue Number
AL1203F
Purity
≥ 98%
Molecular Weight
120.58 g/mol

Complies with : IP | BP | USP | EP | ACS

ISO 9001 ISO 14001 GMP COA with every batch

Sign In

Sign in to view pricing and place your order.

Don't have an account? Create one

Key Properties

Appearance Colorless to pale yellow liquid
Shelf Life 12 months
Packaging Available in 100 mL and 500 mL glass bottles
Storage Store in a cool, dry place away from moisture and incompatible materials.

Pivaloyl chloride (2,2-dimethylpropionyl chloride, extra pure) is a bulky, sterically hindered acyl chloride used as an acylating reagent.

Also known as 2,2-Dimethylpropionyl chloride.

Catalogue No.
AL1203F
CAS Number
3282-30-2
Molecular Formula
C5H9ClO
Molecular Weight
120.58 g/mol
HSN Code
29159070
Grade
98% Extra Pure
Product Form
Substance

Colorless to pale yellow liquid with a density of 0.98 g/mL and a pungent odor.

Appearance
Colorless to pale yellow liquid
Shelf Life
12 months
Packaging
Available in 100 mL and 500 mL glass bottles
Storage
Store in a cool, dry place away from moisture and incompatible materials.

1.1 — Product identifier

Chemical Name
Pivaloyl chloride
Catalogue No.
AL1203F
Product form
Substance
CAS Number
3282-30-2
EC Number
222-200-0
Grade
98% Extra Pure
EC Index Number
607-007-00-0
Chemical Formula
C5H9ClO
HSN Code
29159070
Synonyms
2,2-Dimethylpropionyl chloride

1.2 — Relevant identified uses of the substance or mixture and uses advised against

Use of the substance/mixture
Used as an acylating agent in organic synthesis.
Uses advised against
Not specified

1.3 — Details of the supplier of the safety data sheet

Company identification
Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.

1.4 — Emergency Contact Details

Phone / e-Mail
Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in

2.3 — Other hazards

Other hazards
Corrosive to metals; may cause severe skin burns and eye damage.

3.1 — Substance

Name
Pivaloyl chloride
CAS No.
3282-30-2

4.1 — Description of first aid measures

First-aid measures after inhalation
Remove to fresh air. If breathing is difficult, give oxygen. Seek medical attention immediately.
First-aid measures after skin contact
Remove contaminated clothing. Rinse skin with plenty of water for at least 15 minutes. Seek medical attention.
First-aid measures after eye contact
Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
First-aid measures after ingestion
Do not induce vomiting. Rinse mouth and seek medical attention immediately.

4.2 — Most important symptoms and effects, both acute and delayed

Symptoms relating to use
Coughing, shortness of breath, skin burns, eye irritation.

4.3 — Indication of any immediate medical attention and special treatment needed

General information
Treat symptomatically. Show this safety data sheet to the treating physician.

5.1 — Extinguishing media

Suitable extinguishing media
Water spray, carbon dioxide, dry chemical powder, foam.
Unsuitable extinguishing media
Not specified

5.2 — Special hazards arising from the substance or mixture

Special procedures
Flammable liquid; may produce toxic fumes in a fire.

5.3 — Advice for firefighters

Protection during firefighting
Do not enter fire area without proper protective equipment, including respiratory protection.

6.1.1 — For non-emergency personnel

Emergency procedures
Evacuate area. Wear appropriate protective equipment. Contain and collect spillage.

6.3 — Methods and material for containment and cleaning up

Methods for cleaning up
Absorb with inert material and dispose of in accordance with local regulations.

6.4 — Reference to other sections

Reference
Not specified

7.1 — Precautions for safe handling

Precautions for safe handling
Use only in a fume hood with appropriate PPE including gloves and goggles.
Hygiene measures
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.

7.2 — Conditions for safe storage, including any incompatibilities

Storage conditions
Store in tightly closed containers in a cool, dry, well-ventilated area away from heat sources.

8.2 — Exposure controls

Hand protection
Protective gloves (e.g. nitrile rubber)
Eye protection
Chemical safety goggles or safety glasses
Skin and body protection
Wear suitable protective clothing
Respiratory protection
Use appropriate respiratory protection if ventilation is inadequate.

9.1 — Information on basic physical and chemical properties

Physical state
Liquid
Colour
Colorless to pale yellow
Odour
Pungent
Odour threshold
Not specified
pH value
Not applicable
Relative evaporation rate (butylacetate=1)
Not specified
Melting point
-30 °C
Freezing point
Not specified
Boiling point
118 °C
Flash point
25 °C
Auto-ignition temperature
Not specified
Decomposition temperature
Not specified
Flammability (solid, gas)
Flammable liquid
Vapour pressure
Not specified
Relative vapour density at 20°C
Not specified
Density
0.98 g/mL
Solubility
Soluble in organic solvents, reacts with water
Log Pow
Not specified
Viscosity, kinematic
Not specified
Viscosity, dynamic
Not specified
Explosive properties
Not explosive
Oxidising properties
Not oxidizing
Explosive limits
Not specified

10.1 — Reactivity

Reactivity
Reacts violently with water, alcohols, and amines.

10.2 — Chemical stability

Chemical stability
Stable under recommended storage conditions.

10.3 — Possibility of hazardous reactions

Possibility of hazardous reactions
No dangerous reactions known under normal conditions of use.

10.4 — Conditions to avoid

Conditions to avoid
Avoid contact with incompatible materials and excessive heat.

10.5 — Incompatible materials

Incompatible materials
Water, strong bases, strong oxidizing agents.

10.6 — Hazardous decomposition products

Hazardous decomposition products
Not specified

11.1 — Information on toxicological effects

Acute toxicity
Highly toxic; LD50 (oral, rat) 200 mg/kg.
Skin corrosion/irritation
Causes severe skin burns.
Serious eye damage/irritation
Causes serious eye damage.
Respiratory or skin sensitisation
May cause allergic skin reactions.
Germ cell mutagenicity
Not classified
Carcinogenicity
Not classified
Specific target organ toxicity (single exposure)
May cause respiratory irritation.
Specific target organ toxicity (repeated exposure)
Not classified

12.1 — Toxicity

Toxicity information
Not specified

12.2 — Persistence - degradability

Persistence - degradability
Not specified

12.3 — Bioaccumulative potential

Bioaccumulative potential
Not specified

12.4 — Mobility in soil

Mobility in soil
Not specified

12.6 — Other adverse effects

Environmental precautions
Not specified

13.1 — Waste treatment methods

Additional Info
Dispose of contents/container in accordance with local, regional, national and international regulations.

14.1 — UN number

UN-No. (ADR)
UN 2438
UN-No. (IMDG)
UN 2438
UN-No. (IATA)
UN 2438
UN-No. (ADN)
UN 2438
UN-No. (RID)
UN 2438

14.2 — UN proper shipping name

Proper Shipping Name (ADR)
Pivaloyl chloride
Proper Shipping Name (IMDG)
Pivaloyl chloride
Proper Shipping Name (IATA)
Pivaloyl chloride
Proper Shipping Name (ADN)
Pivaloyl chloride
Proper Shipping Name (RID)
Pivaloyl chloride

14.3 — Transport hazard class(es)

Transport hazard class(es)
6.1

14.4 — Packing group

Packing group (ADR)
I
Packing group (IMDG)
I
Packing group (IATA)
I
Packing group (ADN)
I
Packing group (RID)
I

14.5 — Environmental hazards

Dangerous for the environment
Not specified
Marine pollutant
Not specified
Other information
No supplementary information available

15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture

15.1.1 EU-Regulations
Not specified

Used as a bulky acylating reagent for selective protection of primary alcohols/amines in organic synthesis.

ISO 9001 ISO 14001 GMP COA with every batch
Batch Number
AL-2026-AL1203F
Manufacturing Date
September-2026
Expiry Date
September-2031
Molecular Weight
120.58 g/mol
Test Standard Observed
Assay ≥ 98% 99.5%
Density 0.98 g/mL 0.98 g/mL
Boiling Point 118 °C 118 °C
Moisture Content ≤ 0.5% 0.3%
Related Substances Not more than 1% 0.5%

The above product is expected to comply with 98% Extra Pure grade specification.

Technical Data Sheet

Grade Assay/Purity Melting/Boiling Point Moisture/LOD Residue on Ignition Related Substances Solubility
98% Extra Pure ≥ 98% Boiling point: 118 °C ≤ 0.5% Not applicable Not more than 1% Soluble in organic solvents
View full Technical Data Sheet

Related Products

View All

Why buy from Alpha Chemika

Trusted Quality ISO 9001:2015 Certified
Global Supply 125+ Countries Served
Complete Documentation COA, MSDS, TDS & more
Expert Support We're here to help

What Our Scientific & Industrial Customers Say

“Speedy delivery, professional staff.”

Sonica Lokhandwala

“One shop stop for all laboratory chemicals requirements.”

Adebowale Idris

“Exactly as advertised.”

Babatunde Ugwuanyi

“Alpha Chemika products are of excellent quality. Highly satisfied.”

Jack Roberts

“From ordering to shipping, every course of action was smooth. Timely delivery.”

Priti Mourya

“Completely satisfied with the products and services.”

Hitu Kunjathur
FAQs

Common Questions About Laboratory Chemicals & Solutions

Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.

Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.

Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.

Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.

Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.

Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.

Connect with Us for Your Requirements

Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.

Email Address info@alphachemika.net
Phone Number +91 9769472001

Request a Quote

Tell us about your requirement, and our team will get back to you with the right product recommendations and technical support.

  • No countries found

Fields marked * are required. By submitting this form you agree to be contacted by Alpha Chemika regarding your enquiry.

Alpha Chemika Assistant Product search & quotations
Thinking…

items in your quote

Your Quote Request ( items)

Currency: