Platinum ICP Standard Solution
- CAS Number
- -
- HSN Code
- 38229090
- Molecular Formula
- Pt compound in dilute HCl
- Catalogue Number
- AL1207C
- Purity
- 1000 mg/L Pt
- Molecular Weight
- 195.08 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Platinum ICP standard solution is a certified reference solution used to calibrate ICP spectrometers for platinum determination. It provides a reliable standard for accurate quantitative analysis of platinum in various samples.
Also known as Platinum standard solution, Platinum calibration solution.
- Catalogue No.
- AL1207C
- CAS Number
- -
- Molecular Formula
- Pt compound in dilute HCl
- Molecular Weight
- 195.08 g/mol
- HSN Code
- 38229090
- Grade
- 1000 mg/L in Hydrochloric Acid
- Product Form
- Mixture
Clear, colorless to pale yellow acidic aqueous solution with a density of 1.034 g/mL. The solution is prepared in hydrochloric acid, ensuring stability and solubility of platinum ions.
- Appearance
- Clear, colorless to pale yellow solution
- Shelf Life
- -
- Packaging
- -
- Storage
- Store in a cool, dry place away from incompatible materials.
1.1 — Product identifier
- Chemical Name
- Platinum ICP Standard Solution
- Catalogue No.
- AL1207C
- Product form
- Mixture
- CAS Number
- Not applicable
- EC Number
- Not applicable
- Grade
- 1000 mg/L in Hydrochloric Acid
- EC Index Number
- Not applicable
- Chemical Formula
- Pt compound in dilute HCl
- HSN Code
- 38229090
- Synonyms
- Platinum standard solution, Platinum calibration solution
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Calibration of ICP spectrometers for platinum determination
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Corrosive to metals; may cause skin and eye irritation.
3.1 — Substance
- Name
- Platinum ICP Standard Solution
- CAS No.
- Not applicable
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with plenty of soap and water. If irritation develops, seek medical attention.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Rinse mouth. Do not induce vomiting. Seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Irritation of skin, eyes, and respiratory tract; potential corrosive effects.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Non-flammable, but may emit toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Contain spill and absorb with inert material. Dispose of in accordance with local regulations.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Neutralize with appropriate agents and dispose of as hazardous waste.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use personal protective equipment (PPE) such as gloves and goggles. Avoid contact with skin and eyes.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place, away from incompatible materials such as strong bases and oxidizers.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Clear, colorless to pale yellow
- Odour
- Slightly acidic
- Odour threshold
- Not applicable
- pH value
- < 1
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- Not applicable
- Freezing point
- Not applicable
- Boiling point
- Not applicable
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not applicable
- Flammability (solid, gas)
- Not applicable
- Vapour pressure
- Not applicable
- Relative vapour density at 20°C
- Not applicable
- Density
- 1.034 g/mL
- Solubility
- Soluble in water and hydrochloric acid
- Log Pow
- Not applicable
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not applicable
- Oxidising properties
- Not applicable
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions. Avoid contact with strong bases and oxidizing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong bases, oxidizing agents, and reactive metals.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Not classified as acutely toxic; however, may cause irritation.
- Skin corrosion/irritation
- Causes skin irritation.
- Serious eye damage/irritation
- Causes serious eye irritation.
- Respiratory or skin sensitisation
- Not classified as a sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- Not classified as a specific target organ toxicant.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 1789
- UN-No. (IMDG)
- UN 1789
- UN-No. (IATA)
- UN 1789
- UN-No. (ADN)
- UN 1789
- UN-No. (RID)
- UN 1789
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Hydrochloric acid solution
- Proper Shipping Name (IMDG)
- Hydrochloric acid solution
- Proper Shipping Name (IATA)
- Hydrochloric acid solution
- Proper Shipping Name (ADN)
- Hydrochloric acid solution
- Proper Shipping Name (RID)
- Hydrochloric acid solution
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 8
14.4 — Packing group
- Packing group (ADR)
- III
- Packing group (IMDG)
- III
- Packing group (IATA)
- III
- Packing group (ADN)
- III
- Packing group (RID)
- III
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
This solution is primarily used to calibrate ICP-OES and ICP-MS instruments for quantitative analysis of platinum in environmental, geological, and industrial samples.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL1207C
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 195.08 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay (Platinum) | 1000 mg/L ± 5% | 995 mg/L |
| Density | 1.034 g/mL ± 0.005 g/mL | 1.033 g/mL |
| pH | < 1 | 0.8 |
| Appearance | Clear, colorless to pale yellow | Clear, pale yellow |
| Related Substances | None detected | None detected |
The above product is expected to comply with 1000 mg/L in Hydrochloric Acid grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 1000 mg/L in Hydrochloric Acid | 1000 mg/L Pt | Not applicable | Not specified | Not specified | Not specified | Soluble in water and hydrochloric acid |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.