Rubeanic Acid Solution
- CAS Number
- -
- HSN Code
- 38229090
- Molecular Formula
- C2H4N2S2
- Catalogue Number
- AL1296A
- Purity
- >95%
- Molecular Weight
- 120.20 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Rubeanic acid solution, also known as dithioxamide solution, is a specialized reagent used primarily for the detection of metal ions, particularly copper and nickel. This ready-to-use solution is formulated for convenience in analytical chemistry applications, allowing for immediate use without the need for further preparation. Rubeanic acid is notable for its ability to form colored complexes with certain metal ions, making it a valuable tool in various analytical procedures. The solution is provided in a stable form, ensuring consistent performance in laboratory settings.
Also known as Dithioxamide solution.
- Catalogue No.
- AL1296A
- CAS Number
- -
- Molecular Formula
- C2H4N2S2
- Molecular Weight
- 120.20 g/mol
- HSN Code
- 38229090
- Grade
- Ready-to-use solution
- Product Form
- Mixture
The Rubeanic acid solution appears as a clear to pale liquid, with a density ranging from 0.79 to 0.86 g/mL. It is characterized by its flammable nature, being an alcohol-based solution. The boiling point of Rubeanic acid is approximately 200 °C, while the melting point is around 50 °C. The solution is soluble in water and organic solvents, which enhances its versatility in different analytical applications. The pH of the solution is typically neutral, making it compatible with a variety of chemical environments.
- Appearance
- Clear to pale liquid
- Shelf Life
- 12 months
- Packaging
- Available in 100 mL and 500 mL bottles
- Storage
- Store in a cool, dry place away from ignition sources.
1.1 — Product identifier
- Chemical Name
- Rubeanic Acid Solution
- Catalogue No.
- AL1296A
- Product form
- Mixture
- CAS Number
- Not applicable
- EC Number
- Not applicable
- Grade
- Ready-to-use solution
- EC Index Number
- Not applicable
- Chemical Formula
- C2H4N2S2
- HSN Code
- 38229090
- Synonyms
- Dithioxamide solution
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Metal-ion detection reagent
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Flammable liquid; may cause skin and eye irritation.
3.1 — Substance
- Name
- Rubeanic Acid Solution
- CAS No.
- Not applicable
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with soap and water. If irritation occurs, seek medical attention.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. If irritation persists, seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Irritation of eyes, skin, and respiratory tract; headache; dizziness.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Flammable; may produce toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and eliminate all ignition sources. Contain spill and absorb with inert material.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Collect and dispose of in accordance with local regulations.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use in a well-ventilated area. Avoid contact with skin and eyes. Wear appropriate protective equipment.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place away from heat and ignition sources.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Clear to pale
- Odour
- Slightly pungent
- Odour threshold
- Not determined
- pH value
- Neutral
- Relative evaporation rate (butylacetate=1)
- Not determined
- Melting point
- 50 °C
- Freezing point
- Not determined
- Boiling point
- 200 °C
- Flash point
- Not determined
- Auto-ignition temperature
- Not determined
- Decomposition temperature
- Not determined
- Flammability (solid, gas)
- Flammable liquid
- Vapour pressure
- Not determined
- Relative vapour density at 20°C
- Not determined
- Density
- 0.79-0.86 g/mL
- Solubility
- Soluble in water and organic solvents
- Log Pow
- Not determined
- Viscosity, kinematic
- Not determined
- Viscosity, dynamic
- Not determined
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- Not determined
10.1 — Reactivity
- Reactivity
- Stable under normal conditions; avoid heat and ignition sources.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong oxidizing agents, strong acids, and bases.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Low toxicity; may cause irritation.
- Skin corrosion/irritation
- May cause skin irritation.
- Serious eye damage/irritation
- May cause eye irritation.
- Respiratory or skin sensitisation
- Not expected to be a sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- Not classified as a specific target organ toxicant.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 1170
- UN-No. (IMDG)
- UN 1170
- UN-No. (IATA)
- UN 1170
- UN-No. (ADN)
- UN 1170
- UN-No. (RID)
- UN 1170
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Flammable liquid, n.o.s.
- Proper Shipping Name (IMDG)
- Flammable liquid, n.o.s.
- Proper Shipping Name (IATA)
- Flammable liquid, n.o.s.
- Proper Shipping Name (ADN)
- Flammable liquid, n.o.s.
- Proper Shipping Name (RID)
- Flammable liquid, n.o.s.
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 3
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Rubeanic acid solution is primarily utilized in analytical chemistry as a colorimetric reagent for the determination of copper and nickel ions in various samples. It is widely used in environmental testing, metallurgy, and quality control processes in industries such as mining and metal processing. Additionally, this reagent can be employed in educational laboratories for teaching purposes, demonstrating metal ion detection techniques. Its ability to form distinct colored complexes with target ions makes it an essential tool for chemists in both research and industrial applications.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL1296A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 120.20 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay | >95% | >95% |
| Density | 0.79-0.86 g/mL | 0.82 g/mL |
| pH | Neutral | 7.0 |
| Appearance | Clear to pale liquid | Clear liquid |
| Moisture content | <5% | 3.2% |
The above product is expected to comply with Ready-to-use solution grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| Ready-to-use solution | >95% | 50 °C / 200 °C | <5% | <1% | None detected | Soluble in water and organic solvents |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.