Tellurium AAS Standard Solution
- CAS Number
- -
- HSN Code
- 38229090
- Molecular Formula
- Te in HCl
- Catalogue Number
- AL1496B
- Purity
- 1000 mg/L
- Molecular Weight
- 127.60 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Tellurium AAS standard solution is a certified reference solution specifically designed for the calibration of atomic absorption spectrophotometers (AAS) in the determination of tellurium concentrations. This solution contains tellurium at a concentration of 1000 mg/L in hydrochloric acid, providing a reliable standard for analytical procedures. The molecular weight of tellurium is 127.60 g/mol, and the solution is prepared in a dilute hydrochloric acid medium, which aids in the stability and solubility of the tellurium compound. This product is essential for laboratories engaged in environmental monitoring, materials testing, and quality control processes where accurate tellurium measurement is critical.
Also known as Tellurium Calibration Standard, Tellurium Reference Solution.
- Catalogue No.
- AL1496B
- CAS Number
- -
- Molecular Formula
- Te in HCl
- Molecular Weight
- 127.60 g/mol
- HSN Code
- 38229090
- Grade
- 1000 mg/L in Hydrochloric Acid
- Product Form
- Mixture
The tellurium AAS standard solution is a clear, colorless liquid with an acidic pH due to the presence of hydrochloric acid. It is a stable aqueous solution that exhibits good solubility characteristics for tellurium compounds. The density of the solution is approximately 1.1 g/cm³, and it has a boiling point of around 100 °C, typical for aqueous solutions. The solution is corrosive and should be handled with care, using appropriate personal protective equipment. It is important to note that the solution is not flammable and does not have a distinct odor, making it suitable for laboratory environments.
- Appearance
- Clear, colorless liquid
- Shelf Life
- -
- Packaging
- Available in 100 mL and 500 mL bottles
- Storage
- Store in a cool, dry place away from incompatible materials.
1.1 — Product identifier
- Chemical Name
- Tellurium AAS Standard Solution
- Catalogue No.
- AL1496B
- Product form
- Mixture
- CAS Number
- Not applicable
- EC Number
- Not applicable
- Grade
- 1000 mg/L in Hydrochloric Acid
- EC Index Number
- Not applicable
- Chemical Formula
- Te in HCl
- HSN Code
- 38229090
- Synonyms
- Tellurium Calibration Standard, Tellurium Reference Solution
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Calibration of atomic absorption spectrophotometers for tellurium analysis
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Corrosive and toxic; may cause skin and eye irritation.
3.1 — Substance
- Name
- Tellurium AAS Standard Solution
- CAS No.
- Not applicable
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash skin thoroughly with soap and water. Seek medical attention if irritation develops.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Symptoms of exposure may include irritation of the skin, eyes, and respiratory tract.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Non-flammable, but may emit toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Contain spill and absorb with inert material. Dispose of in accordance with local regulations.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Use appropriate personal protective equipment and ventilate area. Clean up spills immediately.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Handle with gloves and eye protection. Avoid contact with skin and eyes.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place, away from incompatible materials such as strong bases and oxidizers.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Odourless
- Odour threshold
- Not applicable
- pH value
- < 1 (acidic)
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- Not applicable
- Freezing point
- Not applicable
- Boiling point
- 100 °C
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not applicable
- Flammability (solid, gas)
- Not flammable
- Vapour pressure
- Not applicable
- Relative vapour density at 20°C
- Not applicable
- Density
- 1.1 g/cm³
- Solubility
- Soluble in water
- Log Pow
- Not applicable
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions, but may react with strong bases and oxidizing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong bases, oxidizing agents, and reactive metals.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Toxic if ingested or inhaled; may cause respiratory irritation.
- Skin corrosion/irritation
- Causes skin irritation.
- Serious eye damage/irritation
- Causes serious eye irritation.
- Respiratory or skin sensitisation
- May cause allergic skin reactions in sensitive individuals.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause damage to organs through prolonged or repeated exposure.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 3264
- UN-No. (IMDG)
- UN 3264
- UN-No. (IATA)
- UN 3264
- UN-No. (ADN)
- UN 3264
- UN-No. (RID)
- UN 3264
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Corrosive liquid, acidic, inorganic, n.o.s.
- Proper Shipping Name (IMDG)
- Corrosive liquid, acidic, inorganic, n.o.s.
- Proper Shipping Name (IATA)
- Corrosive liquid, acidic, inorganic, n.o.s.
- Proper Shipping Name (ADN)
- Corrosive liquid, acidic, inorganic, n.o.s.
- Proper Shipping Name (RID)
- Corrosive liquid, acidic, inorganic, n.o.s.
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 8
14.4 — Packing group
- Packing group (ADR)
- III
- Packing group (IMDG)
- III
- Packing group (IATA)
- III
- Packing group (ADN)
- III
- Packing group (RID)
- III
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
This tellurium AAS standard solution is primarily used for the calibration of atomic absorption spectrophotometers, which are widely employed in laboratories for quantitative analysis of tellurium in various samples. Industries such as environmental testing, metallurgy, and semiconductor manufacturing utilize this solution to ensure accurate measurements of tellurium levels in materials and waste products. Additionally, it serves as a reference standard in research and development settings where tellurium's properties and applications are being studied. The solution is also valuable in regulatory compliance testing, ensuring that tellurium concentrations in products meet safety and environmental standards.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL1496B
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 127.60 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay (Tellurium) | 1000 mg/L ± 5% | 1000 mg/L |
| pH | < 1 | 0.8 |
| Density | 1.1 g/cm³ | 1.1 g/cm³ |
| Appearance | Clear, colorless solution | Clear, colorless solution |
The above product is expected to comply with 1000 mg/L in Hydrochloric Acid grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 1000 mg/L in Hydrochloric Acid | 1000 mg/L | Not applicable | Not specified | Not specified | Not specified | Soluble in water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.