Tetrabutylammonium perchlorate
- CAS Number
- 1923-70-2
- HSN Code
- 29239000
- Molecular Formula
- C16H36ClNO4
- Catalogue Number
- AL2563A
- Purity
- ≥99%
- Molecular Weight
- 341.91 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Tetrabutylammonium perchlorate is a stable, weakly coordinating anion salt that serves as an important electrolyte in electrochemistry research. This compound is notable for its high purity of 99%, making it suitable for sensitive applications in laboratory settings. With a molecular formula of C16H36ClNO4 and a molecular weight of 341.91 g/mol, it is classified as an ammonium salt. Due to its oxidizing properties, it is subject to regulatory end-use control, ensuring safe handling and application in research environments.
Also known as TBAClO4.
- Catalogue No.
- AL2563A
- CAS Number
- 1923-70-2
- Molecular Formula
- C16H36ClNO4
- Molecular Weight
- 341.91 g/mol
- HSN Code
- 29239000
- Grade
- 99%
- Product Form
- Substance
Tetrabutylammonium perchlorate appears as a white crystalline powder. It is soluble in various organic solvents, which enhances its utility in electrochemical applications. The compound has a melting point that typically ranges around 100-120 °C, although specific values can vary based on purity and environmental conditions. Its density is approximately 1.1 g/cm³, and it has a low vapor pressure, indicating minimal volatility under standard conditions. The compound is stable under normal conditions but should be stored away from heat sources and combustibles due to its oxidizing nature.
- Appearance
- White crystalline powder
- Shelf Life
- -
- Packaging
- -
- Storage
- Store in a cool, dry place away from heat sources and combustibles.
1.1 — Product identifier
- Chemical Name
- Tetrabutylammonium perchlorate
- Catalogue No.
- AL2563A
- Product form
- Substance
- CAS Number
- 1923-70-2
- EC Number
- 217-070-0
- Grade
- 99%
- EC Index Number
- Not specified
- Chemical Formula
- C16H36ClNO4
- HSN Code
- 29239000
- Synonyms
- TBAClO4
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Electrolyte in electrochemistry research
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Oxidizer; may cause fire or explosion in contact with combustible materials.
3.1 — Substance
- Name
- Tetrabutylammonium perchlorate
- CAS No.
- 1923-70-2
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with soap and water. If irritation occurs, seek medical attention.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. If irritation persists, seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- May cause irritation to skin, eyes, and respiratory tract.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Oxidizer; may enhance combustion of other materials.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and eliminate all ignition sources. Contain spill and prevent entry into waterways.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Use appropriate protective equipment. Sweep up and place in a suitable container for disposal.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Avoid contact with skin and eyes. Use in a well-ventilated area and avoid inhalation of dust.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place, away from heat and incompatible materials.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if dust is generated.
9.1 — Information on basic physical and chemical properties
- Physical state
- Solid
- Colour
- White
- Odour
- Odourless
- Odour threshold
- Not applicable
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- 100-120 °C
- Freezing point
- Not applicable
- Boiling point
- Not applicable
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Not flammable under normal conditions
- Vapour pressure
- Low
- Relative vapour density at 20°C
- Not applicable
- Density
- ~1.1 g/cm³
- Solubility
- Soluble in organic solvents
- Log Pow
- Not specified
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not explosive
- Oxidising properties
- Oxidizer
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions; may react with strong reducing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong reducing agents, combustible materials.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Not classified as acutely toxic; however, may cause irritation.
- Skin corrosion/irritation
- May cause mild irritation.
- Serious eye damage/irritation
- May cause irritation.
- Respiratory or skin sensitisation
- Not a sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- Not classified as a specific target organ toxicant.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- UN 1479
- UN-No. (IMDG)
- UN 1479
- UN-No. (IATA)
- UN 1479
- UN-No. (ADN)
- UN 1479
- UN-No. (RID)
- UN 1479
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Tetrabutylammonium perchlorate
- Proper Shipping Name (IMDG)
- Tetrabutylammonium perchlorate
- Proper Shipping Name (IATA)
- Tetrabutylammonium perchlorate
- Proper Shipping Name (ADN)
- Tetrabutylammonium perchlorate
- Proper Shipping Name (RID)
- Tetrabutylammonium perchlorate
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 5.1
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Tetrabutylammonium perchlorate is primarily used as an electrolyte reference compound in cyclic voltammetry and other electrochemical research applications. Its weakly coordinating anion properties make it ideal for studying ion transport and reaction mechanisms in various electrochemical systems. Additionally, it finds applications in the development of electrochemical sensors and batteries, where precise control of ionic conductivity is essential. The compound is also utilized in the synthesis of other chemical compounds in research laboratories, particularly in studies involving ionic liquids and organic synthesis.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL2563A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 341.91 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay | ≥99% | 99.5% |
| Moisture Content | ≤0.5% | 0.3% |
| Residue on Ignition | ≤0.1% | 0.05% |
| Related Substances | None detected | None detected |
| Solubility | Soluble in organic solvents | Soluble in ethanol and acetone |
The above product is expected to comply with 99% grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 99% | ≥99% | 100-120 °C | ≤0.5% | ≤0.1% | None detected | Soluble in organic solvents |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.