Uranyl magnesium acetate solution
- CAS Number
- -
- HSN Code
- 38229090
- Molecular Formula
- C4H6MgN2O8U
- Catalogue Number
- AL1561A
- Purity
- N/A
- Molecular Weight
- N/A
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Uranyl magnesium acetate solution (magnesium uranyl acetate solution) is a specialized reagent that contains uranyl ions and magnesium ions in an acetate medium. This solution is notable for its use in analytical chemistry, particularly in the gravimetric determination of sodium ions. Due to its radioactive nature, it is subject to strict regulatory controls and requires an end-use certificate for purchase. The solution is typically prepared to a specific concentration for laboratory applications, ensuring consistent performance in analytical procedures.
Also known as Magnesium uranyl acetate solution.
- Catalogue No.
- AL1561A
- CAS Number
- -
- Molecular Formula
- C4H6MgN2O8U
- Molecular Weight
- N/A
- HSN Code
- 38229090
- Grade
- Ready-to-use solution
- Product Form
- Mixture
The product appears as a yellow liquid, indicative of the presence of uranyl ions. It has a density of approximately 1.1 g/cm³, which is typical for solutions containing heavy metal ions. The solution is soluble in water, allowing for easy application in various analytical methods. The boiling point is not specifically defined due to the nature of the solution, but it is expected to be above 100°C, while the freezing point is also not specified but is likely to be below 0°C due to the presence of solutes.
- Appearance
- Yellow liquid
- Shelf Life
- -
- Packaging
- -
- Storage
- Store in a cool, dry place, away from direct sunlight and incompatible materials.
1.1 — Product identifier
- Chemical Name
- Uranyl magnesium acetate solution
- Catalogue No.
- AL1561A
- Product form
- Mixture
- CAS Number
- Not applicable
- EC Number
- Not applicable
- Grade
- Ready-to-use solution
- EC Index Number
- Not applicable
- Chemical Formula
- C4H6MgN2O8U
- HSN Code
- 38229090
- Synonyms
- Magnesium uranyl acetate solution
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Analytical reagent for sodium precipitation
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.3 — Other hazards
- Other hazards
- Radioactive material; handle with care and appropriate PPE.
3.1 — Substance
- Name
- Uranyl magnesium acetate solution
- CAS No.
- Not applicable
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If symptoms persist, seek medical attention.
- First-aid measures after skin contact
- Wash with soap and water. If irritation occurs, seek medical attention.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Symptoms of exposure may include respiratory irritation, skin irritation, and eye irritation.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Non-flammable; however, radioactive materials require special handling in case of fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and ensure proper ventilation. Wear appropriate PPE during cleanup.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Contain spill and absorb with inert material. Dispose of in accordance with local regulations for radioactive waste.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use appropriate personal protective equipment (PPE) including gloves and goggles. Avoid inhalation and contact with skin.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Store in a cool, dry place, away from incompatible materials and direct sunlight.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Yellow
- Odour
- Odourless
- Odour threshold
- Not applicable
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- Not applicable
- Freezing point
- Not applicable
- Boiling point
- Not applicable
- Flash point
- Not applicable
- Auto-ignition temperature
- Not applicable
- Decomposition temperature
- Not applicable
- Flammability (solid, gas)
- Not applicable
- Vapour pressure
- Not applicable
- Relative vapour density at 20°C
- Not applicable
- Density
- ~1.1 g/cm³
- Solubility
- Soluble in water
- Log Pow
- Not applicable
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not applicable
- Oxidising properties
- Not applicable
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Stable under normal conditions; avoid contact with strong acids or bases.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- No dangerous reactions known under normal conditions of use.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong acids, strong bases, and oxidizing agents.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- Toxic if ingested or inhaled; may cause radiation exposure.
- Skin corrosion/irritation
- May cause skin irritation upon contact.
- Serious eye damage/irritation
- May cause serious eye irritation.
- Respiratory or skin sensitisation
- Not expected to be a skin sensitizer.
- Germ cell mutagenicity
- Not classified
- Carcinogenicity
- Not classified
- Specific target organ toxicity (single exposure)
- May cause damage to organs through prolonged or repeated exposure.
- Specific target organ toxicity (repeated exposure)
- Not classified
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- Not assigned
- UN-No. (IMDG)
- Not assigned
- UN-No. (IATA)
- Not assigned
- UN-No. (ADN)
- Not assigned
- UN-No. (RID)
- Not assigned
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Uranyl magnesium acetate solution
- Proper Shipping Name (IMDG)
- Uranyl magnesium acetate solution
- Proper Shipping Name (IATA)
- Uranyl magnesium acetate solution
- Proper Shipping Name (ADN)
- Uranyl magnesium acetate solution
- Proper Shipping Name (RID)
- Uranyl magnesium acetate solution
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- Not classified as dangerous goods
14.4 — Packing group
- Packing group (ADR)
- Not applicable
- Packing group (IMDG)
- Not applicable
- Packing group (IATA)
- Not applicable
- Packing group (ADN)
- Not applicable
- Packing group (RID)
- Not applicable
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Uranyl magnesium acetate solution is primarily used in analytical chemistry as a precipitating reagent for the gravimetric determination of sodium ions. This method is particularly useful in environmental testing and quality control in various industries, including pharmaceuticals and materials science. Additionally, due to its radioactive properties, it is utilized in specialized research settings, particularly in studies involving radioactivity and its effects. The solution's unique properties make it valuable in educational laboratories for demonstrating principles of gravimetric analysis.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL1561A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- N/A
| Test | Standard | Observed |
|---|---|---|
| Assay (Purity) | N/A | 99.5% |
| Density | ~1.1 g/cm³ | 1.09 g/cm³ |
| Visual Appearance | Yellow liquid | Yellow liquid |
| pH | N/A | N/A |
The above product is expected to comply with Ready-to-use solution grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| Ready-to-use solution | N/A | N/A | N/A | N/A | N/A | Soluble in water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.